<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-25 00-08-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 73 kHz 14568 19,5497
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,59 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 73 kHz MIN: 11 kHz % above 76 kHz: 19,5497 Acquired: 2026.08.25 0.07.43 Total samples: 14568 Equivalent time: 0:12:08 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,4 dBr MIN: 4,6 dBr AVE: 5,59 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2026.08.25 0.07.42) 23.54 23.56 23.58 00.00 00.02 00.04 00.06 0 2 4 6 Pm [dBr]